Simulasi Perpindahan Panas Pada Pipa Secondary Super Heater (SSH) PLTU 600 MW dengan CFD

Authors

  • Gugum Gumilar Institut Teknologi Nasional
  • Tarsisius Kristyadi Institut Teknologi Nasional

DOI:

https://doi.org/10.55893/jt.vol22no1.517

Keywords:

PLTU, Secondary Super Heater, Computation Fluid Dynamics, Heat Transfer Rate

Abstract

The boiler is an important unit in the PLTU in which there is a Superheater to heat the steam so that increase and becomes superheated steam. The problem is secondary superheater pipe bursts due to excessive heat due to the deposit of the oxide layer in it. This study aims to simulate heat transfer in SSH pipes. with Computational Fluid Dynamics, 3 models are made, without a blockage, blockage at the end, and blockage in the middle. The simulation in a steady state, boiler operational data ; pressure, temperature, velocity flow and mass flow rate. The results show different color profiles for temperature, flow velocity and pressure for the steam and for flue gas. Flue gas heat transfer rate is higher around 800,000 kW, and steam is around 80 kW, Steam mass flow rate is 0.046 kg/s while in the flue gas area it is 0.130 kg/s. The average steam flow rate is around 1 m/s, the maximum is 12 m/s in blocked pipe models, Flue gas flow rate is around 9 to 10 m/s. The average steam temperature is 600°C, and 800°C to 900°C. Steam pressure constant in 16,000,000 Pa and flue gas pressure is 100,000 Pa.

Downloads

Download data is not yet available.

Author Biographies

Gugum Gumilar, Institut Teknologi Nasional

Jurusan Teknik Mesin

Tarsisius Kristyadi , Institut Teknologi Nasional

Jurusan Teknik Mesin

References

Alireza Rezvanpour, Ronald E. Miller. (2022). Scaling analysis as a tool to validate CFD simulation of a lubricant flow in the bearing housing of a gas turbine, Thermal Science and Engineering Progress, Volume 36 Desember 2022, 101513.

Constantine Samaras, Jeffrey A. Drezner, Henry H. Willis and Evan Bloom. (2011). Characterizing the U.S. Industrial Base for Coal-Powered Electricity. Chapter Title: Coal-Fired Power Plant Designs, Systems, and Components RAND Corporation. Stable URL: https://www.jstor.org/stable/10.7249/mg1147netl.11

Dillon, J.J., Desch, P.B., Lai, T.S., Flynn, D.J. (2011). The Nalco Guide to Boiler Failure Analysis, The McGraw-Hill Companies, Inc. USA

Lusiana, Fatayalkadri Citrawati, Erie Martides, Gugum Gumilar. (2019).Analisis Kegagalan Pipa Boiler Superheater Pada Pabrik Kelapa Sawit. Jurnal Ilmiah Teknik Mesin. doi:10.3372/DJITM.V11I1.9357

M.J. Djokosetyardjo, (2003) Ketel uap, Pradnya Paramita, ISBN 9794081213, 2003

Malfin, (2018). Investigasi Performa Perpindahan Panas Winglet Vortex Generator Menggunakan CFD Pada Aliran Internal Pipa Silinder Heat Exchanger. Skripsi. Universitas Sanata Dharma Yogyakarta.

Mariusz Granda, Marcin Trojan, Dawid Taler. (2020). CFD analysis of steam superheater operation in steady and transient State, Energy 199-117423.

M. Ghosh, (2023). Effect of flue gas constituents on boiler tube failure of a captive power plant Engineering Failure Analysis 151 (2023) 107416

Rossi Cahyaningdias dan Ary Bachtiar Krishna Putra. (2019). Studi Numerik Perpindahan Panas Konveksi Paksa pada Pin Fin Berpenampang Circular dengan Susunan Aligned. Jurnal Teknik ITS Vol. 8, No. 2, ISSN: 2337-3539 (2301-9271 Print)

Ryno Laubscher, Pieter Rousseau. (2019). CFD study of pulverized coal-fired boiler evaporator and radiant superheaters at varying loads, Applied Thermal Engineering 160-114057.

Ruben Cabello, et all. (2022). Heat transfer in pipes with twisted tapes: CFD simulations and validation, Computers and Chemical Engineering 166 (2022) 107971

Viki Wahyu Endriyana dkk, (2013). Analisa Unjuk Kerja Secondary Superheater PLTGU Dan Evaluasi Peluang Peningkatan Effectiveness Dengan Cara Variasi Jarak, Jumlah dan Diameter Tube. Jurnal Teknik POMITS Vol. 2, No. 3, ISSN: 2337-3539 (2301-9271 Print)

Additional Files

Published

2023-09-21

How to Cite

Gumilar, G., & Tarsisius Kristyadi. (2023). Simulasi Perpindahan Panas Pada Pipa Secondary Super Heater (SSH) PLTU 600 MW dengan CFD. Jurnal Teknik: Media Pengembangan Ilmu Dan Aplikasi Teknik, 22(1), 65–75. https://doi.org/10.55893/jt.vol22no1.517