Performance Investigation of Cooling Machine Practice Props After Retrofitted by Natural Refrigerants
DOI:
https://doi.org/10.26874/jt.vol20no2.419Keywords:
hydrocarbons, performance, refrigerators, resizing, retrofitAbstract
Resizing the main components of the cooling machine needs to be done after being retrofitted with a new refrigerant. This is done to improve the performance of the cooling engine. In this study, we would like to investigate the effect of adjusting the main components of the cooling machine performance after using new environmentally friendly refrigerants. The experiment was designed on a refrigerator that uses R-134a as a working fluid. The type of hydrocarbon refrigerant used to substitute R-134a is Musicool-22 (MC-22). The cooling load in the evaporator cabin is a salt solution. Testing is done in two stages. In the first stage, the refrigerator operates in its original condition (R-134a with CT1 as the expansion valve). In the second stage, the working fluid R-134a is retrofitted with MC-22 with adjustments to its main components into several variations. Furthermore, the refrigerator performance is measured by comparing the value of the refrigerating effect (RE), the heat of compression, and the refrigerator performance (COP). The test results show that the best refrigerator performance rate is when the refrigerator operates with variation 3 (refrigerant MC-22 with CT2 as the expansion valve), increasing COP values ranging from 0.62% to 2.12%.
References
Aprea, C., Greco, A., & Maiorino, A. (2016). An experimental investigation on the substitution of HFC134a with HFO1234YF in a domestic refrigerator. Applied Thermal Engineering, 106(2016), 959–967. https://doi.org/10.1016/j.applthermaleng.2016.06.098
El-Sayed, A. R., El-Morsi, M., & Mahmoud, N. A. (2018). A Review of the Potential Replacements of HCFC/HFCs Using Environ- mental Friendly Refrigerants. International Journal of Air-Conditioning and Refrigeration. https://doi.org/10.1142/S2010132518300021
Elgendy, E., Hassanain, M., & Fatouh, M. (2015). Assessment of R-438A as a retrofit refrigerant for R-22 in direct expansion water chiller. International Journal of Refrigeration, 50, 127–136. https://doi.org/10.1016/j.ijrefrig.2014.07.017
Fatouh, M., & Abou-Ziyan, H. (2018). Energy and exergy analysis of a household refrigerator using a ternary hydrocarbon mixture in tropical environment – Effects of refrigerant charge and capillary length. Applied Thermal Engineering, 145, 14–26. https://doi.org/10.1016/j.applthermaleng.2018.09.008
Harby, K. (2017). Hydrocarbons and their mixtures as alternatives to environmental unfriendly halogenated refrigerants : An updated overview. Renewable and Sustainable Energy Reviews, 73(February), 1247–1264. https://doi.org/10.1016/j.rser.2017.02.039
Hossain, R., Arafat, A., Fei, A. B., Abu, X., Sujon, S., & Karim, R. (2019). Comparative analysis of refrigerant performance between LPG and R134a under subtropical climate. Journal of Thermal Analysis and Calorimetry. https://doi.org/10.1007/s10973-019-09126-3
Jatinder, G., Ohunakin, O. S., Adelekan, D. S., Atiba, O. E., Daniel, A. B., Singh, J., & Atayero, A. A. (2019). Performance of a domestic refrigerator using selected hydrocarbon working fl uids and TiO 2 – MO nanolubricant. 160(February). https://doi.org/10.1016/j.applthermaleng.2019.114004
Kanna, I. V. (2018). Optimisation of the evaporator of a refrigerator employing hydrocarbon as a refrigerant. International Journal of Ambient Energy, 0(0), 1–8. https://doi.org/10.1080/01430750.2018.1507943
Mohanraj, M. (2019). Experimental investigations on R430A as a drop-in substitute for R134a in domestic refrigerators. Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering, 233(4), 728–738. https://doi.org/10.1177/0954408918796369
Mutaufiq, Sulistyo, H., Berman, E. T., & Wiyono, A. (2019). Investigasi Eksperimental Retrofit Refrigeran Pada Alat Praktik Refrigerator dengan Refrigeran Produk Domestik yang Ramah Lingkungan. Flywheel: Jurnal Teknik Mesin UNTIRTA, V(2), 51–57.
Safety Data Sheet MC-22. (2017). PT Pertamina Persero.
Sari, O., & Balli, M. (2014). From conventional to magnetic refrigerator technology. International Journal of Refrigeration, 37(1), 8–15. https://doi.org/10.1016/j.ijrefrig.2013.09.027
Thavamani, J., & Senthil, R. (2020). Performance analysis of retrofitted domestic vapor compression refrigeration system using hydrocarbon refrigerants. International Journal of Ambient Energy, 0(0), 1–25. https://doi.org/10.1080/01430750.2020.1751284
UNEP. (2015). The Emissions Gap Report 2015 (pp. 1–98). pp. 1–98. Retrieved from https://uneplive.unep.org/media/docs/theme/13/EGR_2015_301115_lores.pdf
Wang, X., & Yu, J. (2015). An experimental investigation on a novel ejector enhanced refrigeration cycle applied in the domestic refrigerator-freezer. Energy, 93, 202–209. https://doi.org/10.1016/j.energy.2015.09.038
Yu, C. C., & Teng, T. P. (2014). Retrofit assessment of refrigerator using hydrocarbon refrigerants. Applied Thermal Engineering, 66(1–2), 507–518. https://doi.org/10.1016/j.applthermaleng.2014.02.050
Additional Files
Published
Issue
Section
License
Copyright (c) 2021 Mutaufiq, Hendri Sulistyo, Kamin Sumardi, Ega Taqwali Berman, Apri Wiyono
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
Penulis yang menyerahkan artikel di Jurnal Teknik: Media Pengembangan dan Aplikasi Teknik untuk keperluan publikasi telah mengetahui bahwa Jurnal Teknik: Media Pengembangan dan Aplikasi Teknik memberikan akses terbuka terhadap konten untuk mendukung pertukaran informasi mengenai ilmu pengetahuan, sesuai dengan penerbitan daring yang berbasis Open Access Journal dan mengikuti Creative Commons Attribution 4.0 International License. Sehingga penulis setuju dengan ketentuan-ketentuan berikut:
1. Penulis memegang hak cipta dan memberikan hak publikasi pertama kepada pihak jurnal dengan pekerjaan secara bersamaan
di bawah Creative Commons Attribution 4.0 International License yang memungkinkan orang lain untuk berbagi pekerjaan
dengan pengakuan kepengarangan karya dan publikasi pertama artikel tersebut di Jurnal Teknik: Media Pengembangan dan
Aplikasi Teknik.
2. Penulis dapat melakukan perjanjian tambahan untuk hak distribusi non-eksklusif artikel yang telah diterbitkan di jurnal ini
(misalnya, posting ke sebuah repositori institusi atau menerbitkannya dalam sebuah buku), dengan mengakui bahwa
publikasi pertama dilakukan di Jurnal Teknik: Media Pengembangan dan Aplikasi Teknik.
3. Penulis diizinkan dan didorong untuk menyebarkan karya mereka secara daring (misalnya, dalam repositori institusi atau
laman web penulis) setelah artikel terbit (proses penerbitan artikel selesai). Hal ini terkait dengan imbas dari pertukaran
informasi yang produktif (Lihat Pengaruh Open Access).